FREQUENCY TRANSFORMERS - OIL-IMMERSED DISTRIBUTION TRANSFORMERS

As a FREQUENCY TRANSFORMER, we offer fast quotes, flexible planning, and on-time delivery for hermetic and oil-immersed distribution transformers with expansion tanks. We offer. With IEC 60076 compliance, low-loss design, and strong short-circuit protection, we provide reliable supply for EPCs, importers, and operators.

Why Oil-Immersed Distribution Transformers?

  • High thermal performance and long life
  • Low total cost of ownership (TCO) and high efficiency
  • Reliability in harsh climates and field conditions
  • Wide range of power/voltage options and accessible service

Why FREQUENCY TRANSFORMERS?

  • Full compliance with IEC/EN 60076 series and EcoDesign efficiency requirements
  • Preliminary quote, transparent delivery time, and scheduled shipment within 24–48 hours
  • Routine/type tests, customer-witnessed FAT, and complete documentation
  • European and Balkan-focused logistics, delivery in accordance with Incoterms.

Product Scope:

  • Hermetically sealed oil-filled distribution transformers (ONAN)
  • Oil-filled transformers with expansion tanks (ONAN/ONAF)
  • Special series with low-loss and low-noise classes
  • Kiosk/container solutions (RMU + Transformer + LV panel integration)

Technical Specifications and Options:

  • Power range: 100 kVA – 10 MVA (higher powers depending on the project)
  • Voltage levels: MV 6–36 kV; LV 0.4–0.8 kV typical
  • Cooling: ONAN; ONAF/ODAF (medium powers) optional
  • Oil options: Mineral oil or natural ester (FR3) – environmental/fire safety
  • Connection groups: Dyn11, YNd1, YNyn0, etc.
  • Losses: Low idle and load losses in accordance with EU/EcoDesign
  • Noise: Low dB(A) designs for 50/60 Hz
  • Accessories: Buchholz relay, pressure relay, oil/level and temperature indicators, protection relays
  • Sensor/monitoring: PT100/NTC, fan control, dry contact outputs
  • Enclosure/finishing: IP23–IP55; C3–C5-M corrosion-rated paint; seismic design option
  • Connection: Cable terminations, bushings, or plug-in connectors; busbar terminals
  • Tests: Routine and type tests, dielectric and thermal tests; Customer-witnessed FAT

Application Areas:

  • Grid MV/LV step-down centers and distribution companies
  • Solar power plants/wind power plants (inverter output and booster applications)
  • Industrial facilities, mining, petrochemical, steel, and infrastructure projects
  • Field installations in rural and harsh climate conditions

Engineering and Integration:

  • Short-circuit withstand and impedance optimization
  • Thermal design for harmonic and dynamic loads (inverter/PCS)
  • Dry contacts and sensor interfaces for SCADA/RTU integration (via panel)
  • Grounding, voltage drop, and protection coordination support
  • Field Logistics: Lifting points, oil filling/draining procedures, and rapid commissioning.

Benefits for importers and EPCs:

  • Fast preliminary offer and technical clarification list in 24–48 hours.
  • Country-specific nameplate, CE/CoC, and multilingual documentation.
  • EXW, FCA, CPT, and DAP delivery options; customs and packaging support.
  • Long-term price stability, flexible ordering, and synchronized shipping.

Frequently Asked Questions:

  • Delivery time? 4–10 weeks depending on power and specifications; part-stock options available.
  • Hermetic or expansion tank? Let's determine together based on maintenance, ambient conditions, and operating preferences.
  • Which oil? Standard mineral oil; natural ester (FR3) may be recommended for fire/environmental criteria.
  • Noise target? We offer low dB(A) options that comply with local regulations.

Call to Action:Contact us with your single-line diagram, load profile, and network parameters to determine the right oil-immersed distribution transformer for your project. We will provide a fast quote, a clear deadline, and reliable delivery.

 
 
Slide 1
Hermetic Type Distribution
Transformers

Long Insulation Life:The transparent insulation oil of the atmosphere does not come into contact with oxygen and insulation deterioration is prevented without oxidation. This extends the insulation life and general service life of the transformer.
Low Maintenance Requirement:No regular maintenance is required other than cleaning under normal conditions and use.
Dimension Advantage:The expansion tank is dimensionally stopped. The transformer, which is the solution to the problem, provides the advantage

Slide 2
Distribution Transformers with Expansion Tanks

Long Insulation Life:Since it is closed to the atmosphere, the insulation oil does not come into contact with oxygen and insulation deterioration caused by oxidation is prevented. This extends the insulation life of the transformer and therefore its service life.

Low Maintenance Requirement:It does not require periodic maintenance other than cleaning under normal conditions and use.

Dimension Advantage:Since there is no expansion tank, the height is reduced in terms of dimensions. This provides an advantage in transformer centers with height problems

Slide 3
Power
Transformers

It is usually designed with an expansion tank. As a cooling element, radiator groups that can be easily installed and removed are preferred. Depending on the characteristics and importance of the place of use, it is common to equip them with more protection equipment than distribution transformers.

Slide 4
Special Type
Transformers

In order to meet the customer's demands for special type transformers that can respond to new and changing needs in industry, distribution and all other areas, our technical team works by consulting with the customer at every stage, listening to their needs and making suggestions. In this process, it projects the needs and offers solutions by immediately putting them into practice.